Skip to main content

Self Installation

With a Self Installation, we ship the T-Connect kit directly to you and your team carries out the fitting on each machine.

This is the right option if you have in-house maintenance or electrical engineers who are comfortable working inside CNC machine cabinets, and you'd rather schedule the rollout around your own production windows.

What arrives​

Each shipment contains, per machine:

  • A T-Connect unit with antenna
  • A DC power cable (for the 24V supply inside the cabinet)
  • One or more current transducers (for spindle power monitoring)
  • Velcro pads for mounting
  • A USB-C cable, in case you ever need to set up its Wi-Fi again

What your team needs​

Before you start
  • A qualified electrical engineer to work inside the machine cabinet — see the safety notice in Power and mounting
  • A 12–24 V DC supply protected by a 500 mA fast-acting fuse (or equivalent circuit protection) upstream of the T-Connect — the unit must be fed from a fused circuit
  • Around 20 minutes of isolated (powered-off) time per machine

How to install​

Your T-Connect arrives already set up for your network. Step-by-step instructions for fitting it — wiring the 24 V supply, then connecting it to the machine with a current clamp, the digital inputs or a direct machine connection — are in Install the T-Connect.

Need help?​

If anything's unclear or your machine cabinet doesn't match what's described in the guide, email support@trackmymachines.com and we'll walk you through it.