Skip to main content

Power and mounting

Every T-Connect is wired the same way for power, whichever way it reads the machine.

danger

All installation tasks must be completed by an authorized, properly qualified and skilled person who:

  • Has read and understood the information presented here
  • Is aware of the possible dangers and acts accordingly
  • Is familiar with electrical machinery
  • Is trained and authorized to work on electrical machinery

Wire the power​

  1. Check the T-Connect for any damage. If it's damaged, contact support.
  2. Isolate the CNC machine.
  3. Screw the antenna onto the T-Connect.
  4. Plug the bootlace ferrule of the positive lead of the DC cable into the 24 V supply in the back of your machine cabinet — there should be many available sockets.
The T-Connect must be downstream of a fuse

Power the unit from a 12–24 V DC supply protected by a 500 mA fast-acting fuse (or equivalent circuit protection) installed upstream of the unit. Make sure the socket you use is on a fused circuit.

The unit's internal resettable fuse, reverse-polarity and surge protection protect the unit only and do not replace external circuit protection.

Which lead is positive?

Both leads end in red bootlace ferrules. The positive lead is the one marked with a dashed white line.

DC power cable: a DC barrel plug at one end; at the other, two leads with red bootlace ferrules, the positive lead marked with a dashed white line
The positive lead is marked with a dashed white line
  1. Plug the other lead into the 0 V or ground supply.
  2. Plug the DC jack into the T-Connect.

Mount it​

  1. Peel the backing off the velcro and attach it to the back of your T-Connect.
  2. Stick it somewhere the Wi-Fi signal can get out of the cabinet — often near the fan outlets — and where the sensor cables will reach.

Don't close the cabinet yet. Next, connect the T-Connect to the machine: current sensing, digital inputs or a machine connection. Not sure which? See Choose how to read your machine.